Applications
Cafés, restaurants, apartments, private houses, pharmacies, laboratories
Description
ECO-ROBUST1500
The ROBUST 1500 system is a four (4) state reverse osmosis system with pressure pump, capable to produce up to 1,890 liters of clean drinking water per day
- Consistent high capacity up to 90 liters per hour
- Recovery rate 60-65% — filter is economical and environmentally-friendly
- Direct flow RO system
- Designed for tankless operation
- CE marked and confirmed to be safe in accordance with EC New Approach Directives
Components
• RObust 1500 New reverse osmosis filter
• Drinking water faucet
• Connection fittings pack
• Service wrenches
• User manual
Filtration
• 5 micron PP sediment filter
• GAC coconut shell carbon filter
• Ecosoft RO membrane element
• CTO carbon post-filter
Replacement filter codes
- CHV3ECO Ecosoft advanced pack of replacement filters 1-2-3 for RO filters
- CSV3012500ECO Ecosoft 500 GPD membrane element
Filter service life
5 000 L but not less than once in 3 months. Service life depends on feed water quality and intensity of usage
Membrane service life
40 000 L but not less than once a year
Specifications
- Brand Ecosoft
- Flow Rate (L/min) 25
- Nominal Micron Rating 001 - 0.0001
- Inlet/Outlet 1/2"
- Min Pressure (bar) 2
- Max Pressure (bar) 5
- Min Temp (degrees c 4
- Max Temp (degrees c) 30
- Application Commercial
- Dimensions 420 × 365 × 297 (H x W X D)
- Flow Capacity 90-100 lph
- Water Consumption 140-150 lph
- Power 230volt
- Power consumption 0.12kw
If pressure of water in your system does not meet requirement, install a pressure booster pump to raise it. If water pressure exceeds the upper limit, install a pressure regulator before the RObust.
Using the RObust with feed water temperature between +20 and +30 °С produces a lower rejection rate and higher flow rate, which yields higher TDS of purified water. Using the system with feed water above +30 °С is
advised against.
Performance
At 25 °С feed water temperature, TDS 1000 mg/L
The water meets the stringent standards set by the Specialty Coffee Association (SCA). Here are the specifications:
Total hardness, meq/L 1.0 - 1.15 1.0 - 2.2
Hydrocarbonate, meq/L 0.8 - 1.0 0.8 - 1.5
pH 6.7 - 7.3 6.0 - 8.0
Requirements
Feed water requirements
- pH 6.5
- TDS, ppm < 1500 ppm CaCO
- Total hardness < 500 ppm CaCO
- Alkalinity < 325 ppm CaCO3
- Active chlorine, ppm < 0,5
- Total iron, ppm < 0,3
- Total manganese, ppm < 0,05
- Chemical oxygen demand, ppm O2
- Total microbial count (TMC), (CFU per 1 mL)<100
- E. coli (CFU per 100 mL) None